Linear response in velocity gauge

From The Yambo Project
Revision as of 09:57, 7 November 2023 by Attacc (talk | contribs)
Jump to navigation Jump to search
Lresp.png

In this tutorial we show how to get the linear response using the velocity gauge instead of the Berry phase approach in length gauge.
We use the same DFT input files of the tutorial Linear response using Dynamical Berry Phase,
run the same setup and remove the symmetries.

Real-time dynamics in velocity gauge

Then in order to calculate the response in velocity gauge we use the command yambo_nl -u p -V resp -F input_lr.in to generate the input:

nlinear                      # [R NL] Non-linear optics
NL_Threads= 1                # [OPENMP/NL] Number of threads for nl-optics
% NLBands
  3 |  6 |                   # [NL] Bands
%
NLstep=   0.0100       fs    # [NL] Real Time step length
NLtime=55.000000      fs    # [NL] Simulation Time
NLintegrator= "INVINT"       # [NL] Integrator ("EULEREXP/RK4/RK2EXP/HEUN/INVINT/CRANKNIC")
NLCorrelation= "IPA"         # [NL] Correlation ("IPA/HARTREE/TDDFT/LRC/JGM/SEX/HF")
NLLrcAlpha= 0.000000         # [NL] Long Range Correction
NLDamping=  0.000000   eV    # [NL] Damping
RADLifeTime=-1.000000      fs    # [RT] Radiative life-time (if negative Yambo sets it equal to Phase_LifeTime in NL)
#EvalCurrent                   # [NL] Evaluate the current
#FrPolPerdic                   # [DIP] Force periodicity of polarization respect to the external field
Gauge= "velocity"                  # [BSE/X] Gauge (length|velocity)
% Field1_Freq
 0.100000 | 0.100000 |         eV    # [RT Field1] Frequency
%
Field1_NFreqs= 1                 # [RT Field1] Frequency
Field1_Int=  1000.00       kWLm2 # [RT Field1] Intensity
Field1_Width= 0.000000     fs    # [RT Field1] Width
Field1_kind=   "DELTA"           # [RT Field1] Kind(SIN|COS|RES|ANTIRES|GAUSS|DELTA|QSSIN)
Field1_pol= "linear"             # [RT Field1] Pol(linear|circular)
% Field1_Dir
   0.000000 | 1.000000 | 0.000000 |        # [RT Field1] Versor
%
Field1_Tstart= 0.010000    fs    # [RT Field1] Initial Time

Notice that in velocity gauge the current is correct while the polarization is calculated using only intra-band dipoles, that anyway is enough for the linear response.

Analysis of the results using YamboPy using polarization

You can get the dielectric constant along the field direction using the same procedure of the Berry Phase case, Fourier transforming the polarization:

import numpy as np
from yambopy import *
from yambopy.plot  import * 

NLDB=YamboNLDB() 

pol =NLDB.Polarization[0]
time=NLDB.IO_TIME_points
t_initial=NLDB.Efield[0]["initial_time"]

pol_damped=np.empty_like(pol)
for i_d in range(3):
   pol_damped[i_d,:]=damp_it(pol[i_d,:],time,t_initial,damp_type='LORENTZIAN',damp_factor=0.1/ha2ev)

Plot_Pol(time=time, pol=pol_damped, xlim=[0,55], save_file='polarization.pdf')

Polarization_velocity

and then calculate the dielectric constant as in the length gauge

Linear_Response(time=time,pol=-pol_damped,efield=NLDB.Efield[0],plot=False,plot_file='eps.pdf')

notice that in this case, only the linear response along the field is correct.

Eps_velocity

Analysis of the results using YamboPy using current