Variables: Difference between revisions
(→Units) |
|||
Line 1: | Line 1: | ||
===Units=== | ===Units=== | ||
* [-] = no unit | * [-] = no unit | ||
* | * Number = any positive integer value | ||
* Energy = RL (integer number of G-vectors), or any of the following: Ha, mHa (Hartree atomic units), Ry, mRy (Rydberg atomic units), eV, meV (electron volts), K, THz, GHz | * Energy = RL (integer number of G-vectors), or any of the following: Ha, mHa (Hartree atomic units), Ry, mRy (Rydberg atomic units), eV, meV (electron volts), K, THz, GHz | ||
* Length = Bohr atomic units a.u. | * Length = Bohr atomic units a.u. |
Revision as of 17:01, 27 March 2017
Units
- [-] = no unit
- Number = any positive integer value
- Energy = RL (integer number of G-vectors), or any of the following: Ha, mHa (Hartree atomic units), Ry, mRy (Rydberg atomic units), eV, meV (electron volts), K, THz, GHz
- Length = Bohr atomic units a.u.
- Time = ps, fs, as
- Magnetic field = T
- Electric field = V/mm
- Angle = deg, rad
Formats
- Range =
Lower limit | Upper limit |
(in the specified Unit) - Integer range =
Lower limit | Upper limit
(integer values) - Vector =
x | y | z |
(in Cartesian coordinates, sandwiched by %)
Ranges can also be split on multiple lines.
Initialization
Variable:
MaxGvecs
(Units: Energy) Meaning: Number of G-vectors in screening
Tip: This determines the size of the dielectric matrix in G-space. Needed for inclusion of local field effects. It should be much smaller than the number of G-vectors needed to expand the wavefunctions. It needs careful convergence.
Optics
Variable:
FFTGvecs
(Units: RL) Meaning: Number of G-vectors used in expanding the wavefunctions and in FFT transforms
Tip: It needs careful convergence. Determines the memory needed.
Variable:
NGBlkXd
(Units: RL) Meaning: Number of G-vectors in the screening.
Tip: Determines the size of the dielectric matrix in G-space. Needed for inclusion of local field effects. It should be much smaller than the number of G-vectors needed to expand the wavefunctions. It needs careful convergence.
Variable:
ETStpsX
(Units: integer) Meaning: Number of energy steps.
Tip: Determines the number of steps in energy the response function/spectrum is computed for in the desired range defined by EnRngeX. Has little effect on memory or time.
EnRngeXd/Xs
(Units: Energy, Format: Range)
Meaning: Energy range the spectrum is calculated across.
Tip: Energy range blah blah
LongDrXd/Xs
(Units: Length, Format: Vector)
Meaning: Electric field direction.
Tip: Electric field direction
Coulomb cutoff
CutRadius
(Units: Length, Format: Real)
Meaning: Sphere/cylinder radius.
Tip: TIP
CUTBox
(Units: Length, Format: Vector)
Meaning: Box sides.
Tip: BOX
GW
Variable:
EXXRLvcs
(Units: RL) Meaning: Number of G-vectors used in the sum of the exchange self-energy Sx.
Tip: It needs careful convergence: not particularly time consuming, large values can be used to ensure convergence.
Variable:
QPkrange
(Units: Integers) Meaning: First and last Indexes of kpoints and bands the slef energy correction is calculated
Tip: If interested in non consecutive kpoints or bands multiple rows can be also considered