Static screening: Difference between revisions

From The Yambo Project
Jump to navigation Jump to search
Line 1: Line 1:
===Static screening matrix ===
''Prerequisites''


Create the input file:
Run [[Initialization]]
 
Run [[Truncated Coulomb potential]] (Only for 2D)
 
 
 
''Create the input file''


  $ yambo -F 02_Ws.in -b -k hartree    (for a 3D material)
  $ yambo -F 02_Ws.in -b -k hartree    (for a 3D material)

Revision as of 20:09, 16 March 2017

Prerequisites

Run Initialization
Run Truncated Coulomb potential (Only for 2D)


Create the input file
$ yambo -F 02_Ws.in -b -k hartree     (for a 3D material)

or

$ yambo -F 02_Ws_2D.in -b -k hartree -r  (for a 2D)

Open the input file Change the size in G-space and the bands of the polarization function as:

% BndsRnXs
  1 |  40 |                 # [Xs] Polarization function bands
%
 NGsBlkXs= 2 Ry  # [Xs] Response block size

Close the input and run the code

$ yambo -F 02_Ws.in  -J 3D

or